{"product_id":"5386642","title":"APC Smart-UPS 3000VA RM 2U LCD 208V uninterruptible power supply (UPS) 3 kVA 2700 W 2 AC outlet(s)","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003eSmart-UPS 3000VA RM 2U LCD 208V\u003ch2\u003eDescription\u003c\/h2\u003e\u003cb\u003eIntuitive LCD interface\u003c\/b\u003e\u003cbr\u003eProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.\u003cbr\u003e\u003cb\u003ePredictive replace battery date\u003c\/b\u003e\u003cbr\u003eDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.\u003cbr\u003e\u003cb\u003eGreen mode\u003c\/b\u003e\u003cbr\u003ePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.\u003cbr\u003e\u003cb\u003eEnergy meter\u003c\/b\u003e\u003cbr\u003eProvides actual kilowatt hours of usage for energy conscious users.\u003cbr\u003e\u003cb\u003eOutlet group control\u003c\/b\u003e\u003cbr\u003eTurn on\/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).\u003cbr\u003e\u003cb\u003eSequenced shutdown and restart\u003c\/b\u003e\u003cbr\u003eConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).\u003cbr\u003e\u003cb\u003ePure sine wave output on battery\u003c\/b\u003e\u003cbr\u003eSimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.\u003cbr\u003e\u003cb\u003eSingle switched outlet group\u003c\/b\u003e\u003cbr\u003eSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on\/off and non-critical load shedding.\u003cbr\u003e\u003cb\u003eWide input voltage range\u003c\/b\u003e\u003cbr\u003eDesigned for harsh electrical environments to save battery life.\u003cbr\u003e\u003cb\u003eStruxureWare\u003c\/b\u003e\u003cbr\u003eCentral compatible Enables centralized management via StruxureWare Central.\u003cbr\u003e\u003cb\u003eBattery failure notification\u003c\/b\u003e\u003cbr\u003eProvides early-warning fault analysis on batteries enabling timely preventive maintenance\u003cbr\u003e\u003cb\u003eHigh online efficiency\u003c\/b\u003e\u003cbr\u003eReduces utlility costs, generates less heat.\u003cbr\u003e\u003cb\u003eLED Indicators\u003c\/b\u003e\u003cbr\u003eProvide easy-to-read status of the unit and utility power conditions.\u003cbr\u003e\u003cb\u003eCold-start capable\u003c\/b\u003e\u003cbr\u003eProvides temporary battery power when the utility power is out.\u003cbr\u003e\u003cb\u003eHot-swappable batteries\u003c\/b\u003e\u003cbr\u003eEnsures clean, uninterrupted power to protected equipment while batteries are being replaced\u003cbr\u003e\u003cb\u003eDisconnected battery notification\u003c\/b\u003e\u003cbr\u003eWarns when a battery is not available to provide backup power.\u003cbr\u003e\u003cb\u003eAutomatic self-test\u003c\/b\u003e\u003cbr\u003ePeriodic battery self-test ensures early detection of a battery that needs to be replaced.\u003cbr\u003eAutomatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.\u003cbr\u003e\u003cb\u003eAdjustable voltage-transfer points\u003c\/b\u003e\u003cbr\u003eMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.\u003cbr\u003e\u003cb\u003eAdjustable voltage sensitivity\u003c\/b\u003e\u003cbr\u003eProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.\u003cbr\u003e\u003cb\u003eAudible alarms\u003c\/b\u003e\u003cbr\u003eProvides notification of changing utility power and UPS conditions\u003cbr\u003e\u003cb\u003eUser-replaceable batteries\u003c\/b\u003e\u003cbr\u003eIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)\u003cbr\u003e\u003cb\u003eUSB connectivity\u003c\/b\u003e\u003cbr\u003eProvides management of the UPS via a USB port (not available on all models).\u003cbr\u003e\u003cb\u003eSerial Connectivity\u003c\/b\u003e\u003cbr\u003eProvides management of the UPS via a serial port.\u003cbr\u003e\u003cb\u003eTemperature-compensated battery charging\u003c\/b\u003e\u003cbr\u003eProlongs battery life by regulating the charge voltage according to battery temperature.\u003cbr\u003e\u003cb\u003eBoost and Trim Automatic\u003c\/b\u003e\u003cbr\u003eVoltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery.\u003cbr\u003e\u003cb\u003eIntelligent battery management\u003c\/b\u003e\u003cbr\u003eMaximizes battery performance, life, and reliability through intelligent, precision charging.\u003cbr\u003e\u003cb\u003eSafety-agency approved\u003c\/b\u003e\u003cbr\u003eEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.\u003cbr\u003e\u003cb\u003eNetwork manageable\u003c\/b\u003e\u003cbr\u003eProvides remote management of the UPS over the network.\u003cbr\u003e\u003cb\u003eFrequency and voltage regulation\u003c\/b\u003e\u003cbr\u003eGives higher application availability by correcting poor frequency and voltage conditions without using the battery.\u003cbr\u003e\u003cb\u003ePredicitive failure notification\u003c\/b\u003e\u003cbr\u003eProvides early-warning fault analysis ensuring proactive component replacement.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBoost and Trim\u003c\/b\u003e\u003cbr\u003eAutomatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery.\u003cbr\u003e\u003cb\u003eIntelligent battery management\u003c\/b\u003e\u003cbr\u003eMaximizes battery performance, life, and reliability through intelligent, precision charging.\u003cbr\u003e\u003cb\u003ePower conditioning\u003c\/b\u003e\u003cbr\u003eProtects connected loads from surges, spikes, lightning, and other power disturbances.\u003cbr\u003e\u003cb\u003eTemperature-compensated battery charging\u003c\/b\u003e\u003cbr\u003eProlongs battery life by regulating the charge voltage according to battery temperature.\u003cbr\u003e\u003cb\u003eAutomatic restart of loads after UPS shutdown\u003c\/b\u003e\u003cbr\u003eAutomatically starts up the connected equipment upon the return of utility power.\u003cbr\u003e\u003cb\u003eAutomatic self-test\u003c\/b\u003e\u003cbr\u003ePeriodic battery self-test ensures early detection of a battery that needs to be replaced.\u003cbr\u003e\u003cb\u003eDisconnected battery notification\u003c\/b\u003e\u003cbr\u003eWarns when a battery is not available to provide backup power.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eNetwork manageable\u003c\/b\u003e\u003cbr\u003eProvides remote management of the UPS over the network.\u003cbr\u003e\u003cb\u003eAudible alarms\u003c\/b\u003e\u003cbr\u003eActively let you know if the unit is on battery, if the battery is low or if there is an overload condition.\u003cbr\u003e\u003cb\u003eLED status indicators\u003c\/b\u003e\u003cbr\u003eQuickly understand unit and power status with visual indicators.\u003cbr\u003e\u003cb\u003eSerial Connectivity\u003c\/b\u003e\u003cbr\u003eProvides management of the UPS via a serial port.\u003cbr\u003e\u003cb\u003eUSB connectivity\u003c\/b\u003e\u003cbr\u003eProvides management of the UPS via a USB port (not available on all models).\u003cbr\u003e\u003cb\u003eDisconnected battery notification\u003c\/b\u003e\u003cbr\u003eWarns when a battery is not available to provide backup power.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eUser-replaceable batteries\u003c\/b\u003e\u003cbr\u003eIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair\u003cbr\u003e\u003cbr\u003eHot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced\u003cbr\u003e\u003cb\u003ePredictive failure notification\u003c\/b\u003e\u003cbr\u003eProvides early-warning fault analysis ensuring proactive component replacement.\u003cbr\u003e\u003cb\u003eResettable circuit breakers\u003c\/b\u003e\u003cbr\u003eEnables a quick recovery from overload events.\u003cbr\u003e\u003cb\u003eBattery failure notification\u003c\/b\u003e\u003cbr\u003eProvides early-warning fault analysis on batteries enabling timely preventive maintenance\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdjustable voltage-transfer points\u003c\/b\u003e\u003cbr\u003eMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.\u003cbr\u003e\u003cb\u003eAdjustable voltage sensitivity\u003c\/b\u003e\u003cbr\u003eProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSafety-agency approved\u003c\/b\u003e\u003cbr\u003eEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e2700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e141 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e255 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e320 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e3 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePerformance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e55 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e2700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e141 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e255 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e320 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e55 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e3 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e2 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eNEMA L6-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB 2.0 ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eBattery\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery recharge time\u003c\/td\u003e\n\u003ctd\u003e3 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eRackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, UL 1778\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-15 - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e23.6 x 38.6 x 10\" (600 x 980 x 254 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e114 lbs (51.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, UL 1778\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e97.7 lbs (44.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e18.9\" (480 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e114 lbs (51.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e3.39\" (86 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e27.2\" (690 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOther features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e23.6 x 38.6 x 10\" (600 x 980 x 254 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":51502506737986,"sku":"SMT3000RMT2U","price":2826.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/3659\/1682\/files\/yEeQ6kFv9EaqbqLutMJkmw.c-m.jpg?v=1768913094","url":"https:\/\/leverify.com\/products\/5386642","provider":"Leverify","version":"1.0","type":"link"}